Description
VN-Plastic Roof – Plastic Centrifugal Roof Fan
The VN-Plastic Roof is a plastic centrifugal roof fan designed for extracting corrosive air, fumes and gases. Its corrosion-resistant plastic construction makes it suitable for industrial environments where chemical exposure can affect conventional metal fans.
The fan features a backward-curved impeller and a directly driven electric motor. Available in different sizes and motor configurations, the VN-Plastic Roof can be selected to suit the required airflow and operating conditions.
When to choose the VN-Plastic Roof
The VN-Plastic Roof is suitable for applications where corrosive air, fumes or gases need to be extracted through a roof-mounted fan. Its plastic construction makes it a good choice for environments where chemical substances may attack conventional metal components.
Typical applications include:
- Electroplating and surface treatment facilities
- Battery rooms and battery charging areas
- Chemical processing industries
- Industrial processes involving corrosive fumes
The fan is designed for handling non-abrasive, corrosive air. Its suitability depends on the chemical composition, concentration and temperature of the extracted air. The material compatibility should therefore always be checked against the specific operating conditions.
Construction and design
The fan casing is manufactured from polyethylene (PE) as standard, while the impeller is made of polypropylene (PP). The backward-curved blade design supports efficient airflow and relatively low energy consumption.
The VN-Plastic Roof features a direct-drive motor, eliminating the need for a separate belt drive. Different motor powers and speeds are available, depending on the selected model.
Options and accessories
Depending on the application, several special configurations are available on request.
Options include:
- Antistatic and self-extinguishing casing (AST)
- Polypropylene (PP) casing
- ATEX Category 3G version
Various accessories are also available to suit the installation requirements, including:
- Flexible connectors
- Gravity-operated dampers
- Manually operated dampers
- Protective guards
Technical specifications
- Fan type: centrifugal roof fan
- Impeller: backward-curved blades
- Impeller diameter: approximately 200–450 mm
- Casing material: polyethylene (PE)
- Impeller material: polypropylene (PP)
- Motor: directly driven asynchronous electric motor
- Motor protection: IP55
- Insulation class: F
- Supply voltage: 230 V single-phase or 400 V three-phase, depending on model
- Motor speeds: 2-, 4- and 6-pole versions, depending on model
- Air temperature: -20 °C to +60 °C
- Duty rating: continuous operation (S1)
Available models and performance
The VN-Plastic Roof is available in several sizes, with impeller diameters ranging from approximately 200 to 450 mm. Different motor powers, speeds and supply voltages are available, depending on the selected model.
Airflow capacity and available pressure vary between models and motor configurations. The required performance should therefore be considered when selecting the appropriate version.
Do you need a specific airflow capacity, pressure or motor configuration that is not listed among the standard options? We can also explore customised configurations to match the technical requirements of your application. The standard models are a starting point, not necessarily the limit of what we can supply.
How to select the right fan
Selecting the right plastic roof fan involves more than choosing the required airflow capacity. The properties of the extracted air and the operating conditions also need to be taken into account.
Consider the following factors when selecting the VN-Plastic Roof:
- Airflow capacity: How much air needs to be extracted per hour?
- Required pressure: What resistance does the fan need to overcome in the ductwork?
- Air composition: Which chemicals, fumes or gases are present, and at what concentrations?
- Temperature: What is the operating temperature of the extracted air?
- Material compatibility: Is the standard PE casing and PP impeller suitable for the chemical exposure?
- Motor configuration: Which supply voltage, motor power and speed are required?
Taking these factors into account helps ensure that the selected fan matches the actual operating conditions.
Advice from Ventinet
Choosing the right plastic roof fan starts with understanding the application. Particularly when handling corrosive air, it is important to consider not only the required airflow and pressure, but also the composition and temperature of the air and the chemical resistance of the materials.
At Ventinet, we look beyond standard product specifications. We work with you to determine the right technical configuration for your application. If your requirements fall outside the standard range, we are happy to explore the possibilities for a customised solution.
As your fan partner, we help you find a fan that matches your technical requirements and operating conditions.
This product is part of our range of roof fans and plastic fans.