[vc_row][vc_column el_class=”main contentbox”][vc_column_text]

ATEX INFORMATION

Two European directives concerning safety with gas and explosion hazards have come into effect through an amendment to Dutch Working Conditions Decree of 1 July 2003. They are Directive 94/9/EC (ATEX 95), which contains the essential health and safety requirements that devices and safety systems have to meet if they are intended for use in places where an explosive atmosphere may occur; and Directive 99/92/ED (ATEX 137), which sets rules for safe working in an explosive environment.

ATEX stands for Atmosphères Explosives. Atex 95 and 137 relate to Articles 95 and 137 respectively of the convention establishing the EC concerning the improvement of the working environment.
The amended Working Conditions Decree stipulates which obligations the employer has to meet if the work is carried out in an explosive environment.

The obligations are as follows:

The Working Conditions Decree contains a transitional law that enables employers to adapt their workplaces to the new rules. Workplaces that were already in use prior to 1 July 2003 must meet the provisions of the amendment decree by 30 June 2006. Workplaces that were taken into use after 1 July 2003 or which have been changed, extended or renovated since that time must comply directly with the new rules. ATEX directive.[/vc_column_text][vc_column_text]

ATEX directive 94/9/EC

From 1 July 2003 all new installations in explosive atmospheres must meet the requirements of the ATEX 94/9/EC directive. ATEX is derived from the French “ATmosphère EXplosible”. The implementation of this new directive began on 1 March 1996 and will become mandatory on 1 July 2003.

The most important change compared to the previous directive is that ATEX applies not only to gas-explosive environments but also to dust-explosive environments.

The various environments are subdivided into three different zones. Gas: zone 0
1 and 2 for Dust; zones 20, 21 and 22.
[/vc_column_text][vc_empty_space][vc_column_text]

ATEX directive 94/9/EC
Classification in two groups:Group 1for underground
Group 2for all other places
Group 1aM1:high risk in mines
M2:less high risk in mines
Group 2Category 1high risk
Category 2risk is likely
Category 3risk is probably rare
[/vc_column_text][vc_column_text]

Division into zones under ATEX 94/9/EC

All zones are subject to separate ATEX certification. A product certified for gas explosion cannot be used in a dust explosive environment.

[/vc_column_text][vc_empty_space][vc_column_text]

Division into zones under ATEX 94/9/EC
Zone 0 or 20 :Gas or dust continuously present
More than 1000 hours a year
Zone 1 or 21 :Gas or dust probably present occasionallyBetween 10 and 1000 hours a year
Zone 2 or 22 :Gas or dust present for short durationLess than 10 hours a year

[/vc_column_text][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column el_class=”main contentbox”][vc_row_inner][vc_column_inner width=”1/3″][vc_single_image image=”1203″ alignment=”center”][/vc_column_inner][vc_column_inner width=”2/3″][vcex_heading text=”What is a “Notified Body””” tag=”h2″][vc_column_text]There are now also straightforward rules for all inspection bodies in Europe. The inspection body that certified the product is stated on all ATEX certified products.[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_row_inner][vc_column_inner el_class=”main contentbox”][vcex_heading text=”Equipment categories” tag=”h2″][vc_column_text]

Zone divisions

Only equipment from a certain category can be used in the various zones. No electrical motors may be used in zones 0 and 20. The various categories are shown in the table above. All motors, apart from ii3D, non-conductive material, must be accompanied by a certificate issued by a ‘Notified Body’. [/vc_column_text][vc_empty_space][vc_column_text]

GASDUST
Zone 1Zone 2Zone 21Zone 22
II 2GII 3GII 2DII 3D
EExn(A)IP55
EExeEExeIP65Non-conductive matter
EExd(e)EExd(e)PTCIP65
EexdEexdConductive matter
[/vc_column_text][vc_empty_space][vc_column_text]

Equipment group

[/vc_column_text][vc_empty_space][vc_column_text]

Division principle (standard EN 50 014)
IElectrical equipment for mines
II Electrical equipment for other situations
IIAIgnition Energy 200 uJ (Propane)
IIBIgnition Energy 60 uJ (Ethylene)
IICIgnition Energy 20 uJ (Hydrogen, Acetylene, Sulphur carbon)

NB: IIA comes within the range of IIB and IIC. IIA is lower in ranking
[/vc_column_text][vc_empty_space][vc_column_text]

Temperature class

[/vc_column_text][vc_empty_space][vc_column_text]

Division principle (standard EN 50 014)
T1Ignition temperature 450°C
T2Ignition temperature 300 °C
T3Ignition temperature 200 °C
T4Ignition temperature 135 °C
T5Ignition temperature 100 °C
T6Ignition temperature 85 °C

[/vc_column_text][vc_empty_space][vc_column_text]NB: T1 falls within the range of T2, etc… T1 is the lowest in ranking. T6 is therefore the ‘heaviest’ version.[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column el_class=”main contentbox”][vc_column_text]